    BECKETT GENISYS ADVANCED OIL BURNER CONTROL
    BECKETT 7505A0000U
    *LOCKOUT TIME: 15 SECONDS
    *VALVE-ON DELAY TIME: N/A
    *MOTOR OFF DELAY TIME: N/A
    Valve-on delay and motor-off delay timings on all models are programmable with Beckett snap-in programming display. Other factory set timings are available. Contact Beckett for alternate timings.
    *FOR CONTROLS WITH ALARM CONTACTS YOU ATTACH THE ALARM CONTACT MODULE WHICH IS SOLD SEPERATELY
    Product Description
    The Beckett GeniSys™ Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell fl ame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 Vac thermostat inputs compatible with both on/off and power stealing thermostats. It can provide interrupted or intermittent duty ignition, and has a 15-second lockout time.
    Features & Benefits
    *Thermostat and boiler control compatible
    *Programmable valve-on delay and motor-off delay
    *Three indicator lights for system monitoring and diagnostics
    *Two communication ports for adding alarm contacts, programming display, and/or future wireless communications
    *Welded relay protection with redundant motor relays
    *Limited reset and limited recycle
    *Sleek, modern design
    *Cad cell resistance indicator
    *Technician Pump Prime mode
    Electrical Ratings
    Inputs
    Voltage: 102 to 132 Vac
    Current: 100 mA plus burner motor, igniter, and valve loads
    Frequency: 60 Hz
    Outputs
    Motor: 120 Vac, 10 full load amps (FLA), 60 locked rotor amps (LRA)
    Note – Reduce motor FLA rating by igniter load
    Igniter: 120 Vac, 3 A @ 0.7 PF min
    Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min
    Thermostat Anticipator Current: 0.1 mA
    Thermostat Voltage: 24 Vac
    Environmental Ratings
    Storage and Operating Ambient Temperature: -40°F to +150°F (-40°C to +65°C)
    Moisture: 5 to 95% RH, non-condensing and non-crystallizing
    Approvals
    REPLACES: HONEYWELL R7184A, R8184G
    NOTE
    *THIS CONTROL IS A 15 SECOND LOCKOUT MAKING IT SAFER THEN THE 45 AND 30 SECOND CONTROLS
    *FOR CONTROLS WITH ALARM CONTACTS YOU ATTACH THE ALARM CONTACT MODULE WHICH IS SOLD SEPERATELY
    ALSO REPLACES CARLIN: 48245, 40200 42230, 42230-02S, 42230-02A, 4223002A 50200
    Beckett snap-in alarm module required for direct replacement of the Carlin 502001
    Please note some of the items require professional knowledge and skills to handle or installed. Thomas New Parts is not responsible for any damage or injuries resulted from mishandling of professional products. All HVACR equipment should be serviced/installed by certified professionals only. Please let us know if you have any concerns or questions.
    Before Opening a Return Request or eBay Resolution Case
    Please contact us through the eBay message center and let us know how we can help!
    Once a case is opened it is difficult to correct your problem!